Tools
Small calculators and guides around snap-fits and plastic part design. Every value with its formula and source.
Sealed housing: pressure and condensation
A tight housing warms up, cools down or travels over a mountain pass. Overpressure and vacuum, force on the lid and each snap-fit hook, bulge of the lid, dew point and how much water comes out inside. Based on: NASA Glenn Research Center, Equation of State and Earth Atmosphere Model; Vaisala, Humidity Conversion Formulas, p. 4, 6–8, 14; DuPont, General Design Principles, Table 4.06; W. L. Gore, Reliability Testing of Protective Vents, p. 2–3.
When it is sealed
Example values. Humidity and temperature of the room where the housing is closed: a dry room or a warm part changes the result a lot.
In use and transport
Example values. The hottest temperature includes the heat of the electronics and of the sun. Hot is taken at the highest altitude and cold at the lowest, each the worst case. Up to 11 000 m.
Lid
Example values. Modulus at the hottest temperature; for a lasting pressure the creep modulus (DuPont p. 21, 25).
Round lid
Rectangular lid
Hooks
Example values. Take the retention force from the calculator ("Retention force"). The seal force is what the hooks must hold anyway to press the seal (O-ring tool).
- metForce per hook 39.12 N against a retention force of 40 N own derivation
- metStress in the lid 7.223 MPa against 30 MPa DuPont, Engineering Polymers – General Design Principles, Module I, table 4.06 (p. 43)
- not metCondensation about 1.879 mg of water or frost at -20 °C Vaisala, Humidity Conversion Formulas B210973JA-F, p. 6, 14; own derivation
- noteVacuum on the seal 140 hPa, as much as 1.43 m of water: a wet seal can suck water in own derivation
- noteIf liquid water is inside the difference when hot grows to 620 hPa, because the water evaporates Vaisala, Humidity Conversion Formulas B210973JA-F, p. 6; own derivation
- noteTest of real housings Sealed 2-litre IP67 housings with a silicone gasket, cooled to −55 °C: one drew in air through the gasket from about 120 hPa of vacuum (−1.75 psi). Housings with a vent showed almost no difference and kept their seal. W. L. Gore, Reliability Testing of GORE Protective Vents in Telecommunication Enclosures, p. 2–3
- Model: a rigid housing, tight, with the same amount of air all the time (NASA Glenn, "Equation of State") and a standard atmosphere (NASA Glenn, "Earth Atmosphere Model – Metric Units"). Weather moves the outside pressure by some more. A lid that bulges makes room and lowers the pressure a little, so the result is on the safe side.
- Humidity: formulas for water above 0 °C and for ice below (Vaisala, Humidity Conversion Formulas B210973JA-F). Parts inside and plastics hold and release moisture and plastics let water vapour through slowly, so a real housing can hold more water than the air alone. Own connection: the same amount of vapour stays in the same volume, so water starts to condense a little below the dew point of the room.
- The lid is treated as a flat plate in the elastic range (DuPont, Table 4.06). Ribs and a domed lid are not counted. A bulge may lift the lid from the seal: compare it with the squeeze of the seal.
- What helps: a pressure-equalising vent instead of a tight box, closing the housing warm and dry, a drying agent, or less air inside.
Open the calculator O-ring seal on a plastic flange
Calculation with your numbers Pro
Calculation in SI units (mm, N, MPa), as in the sources.
Sealed housing
Air pressure when sealing = 966.9 hPa
Formula T = 15.04 − 0.00649 · h; p = 101.29 · ((T + 273.1) / 288.08)^5.256 (kPa)
With your numbers h = 400 m → 966.9 hPa
Air pressure outside at the highest altitude = 795.8 hPa
Formula same formula
With your numbers h = 2000 m → 795.8 hPa
Air pressure outside at the lowest altitude = 966.9 hPa
Formula same formula
With your numbers h = 400 m → 966.9 hPa
Pressure inside when hot = 1120 hPa
Formula p = p₀ · T / T₀, T in K, volume and amount of air constant
With your numbers 966.9 · 343.1 / 296.1 = 1120
Pressure inside when cold = 826.5 hPa
Formula p = p₀ · T / T₀
With your numbers 966.9 · 253.1 / 296.1 = 826.5
Difference when hot, at the highest altitude (inside − outside) = 324.5 hPa
Formula Δp = p_hot − p_outside
With your numbers 1120 − 795.8 = 324.5
Difference when cold, at the lowest altitude (inside − outside) = -140.4 hPa
Formula Δp = p_cold − p_outside
With your numbers 826.5 − 966.9 = -140.4
Lid area under pressure = 6000 mm²
Formula A = a · b
With your numbers 60 · 100 = 6000
Force on the lid = 194.7 N
Formula F = Δp · A (1 hPa = 0.0001 MPa); no outward force without overpressure
With your numbers 324.5 · 0.0001 · 6000 = 194.7
Force per hook = 39.12 N
Formula F_hook = (F + F_seal) / n
With your numbers (194.7 + 40) / 6 = 39.12
Hottest temperature the hooks hold = 72.7 °C
Formula T = T₀ · (p_outside + (n · F_ret − F_seal) / A) / p₀, T in K
With your numbers 296.1 · (795.8 + 333.3) / 966.9 − 273.15 = 72.7
The vacuum equals a water column of = 1.432 m
Formula h = |Δp| / (ρ · g), ρ = 1000 kg/m³
With your numbers 140.4 · 100 / (1000 · 9.80665) = 1.432
Water vapour pressure when sealing = 14.05 hPa
Formula Pw = Pws · RH / 100; Pws = A · 10^(m · T / (T + Tn))
With your numbers 28.09 · 50 / 100 = 14.05
Dew point when sealing = 12.02 °C
Formula Td = Tn / (m / log10(Pw / A) − 1)
With your numbers Pw = 14.05 hPa → 12.02
Water vapour in the air when sealing = 10.28 g/m³
Formula A = C · Pw / T, C = 2.16679 g·K/J, Pw in Pa, T in K
With your numbers 2.16679 · 1405 / 296.1 = 10.28
Water starts to condense in the closed housing at = 11.42 °C
Formula C · Pws(T) / T = A (same amount of vapour in the same volume)
With your numbers A = 10.28 g/m³ → 11.42
Water sealed in = 2.055 mg
Formula m = A · V
With your numbers 10.28 · 200 · 0.001 = 2.055
Water that comes out at the coldest temperature = 1.879 mg
Formula m = (A − A_sat(T_cold)) · V, not below 0
With your numbers (10.28 − 0.8836) · 200 · 0.001 = 1.879
Difference when hot if liquid water is inside = 620.2 hPa
Formula Δp = (p₀ − Pw) · T / T₀ + Pws(T) − p_outside
With your numbers (966.9 − 14.05) · 343.1 / 296.1 + 312 − 795.8 = 620.2
Poisson's ratio = 0.4
Formula ν from E: < 500 → 0.45, 500 … 2500 → 0.40, > 2500 → 0.35
With your numbers ν = 0.4
Largest stress (centre) = 7.223 MPa
Formula σ = 0.75 · a² · p / (t² · (1 + 1.61 · a³/b³))
With your numbers 0.75 · 60² · 0.03245 / (3² · (1 + 1.61 · 0.6³)) = 7.223
Largest deflection (centre) = 0.6238 mm
Formula y = 0.142 · a⁴ · p / (E · t³ · (1 + 2.21 · a³/b³))
With your numbers 0.142 · 60⁴ · 0.03245 / (2400 · 3³ · (1 + 2.21 · 0.6³)) = 0.6238
Saved designs in this browser
No saved designs for this tool yet.
Saved in this browser and, when you are logged in, in your account. Status as the tool calculates it now.
Schematic, not to scale. Use the area inside the seal: only that area is under pressure.