Draft angle for ejection
How much draft does a moulded wall need? Draft from the table of the source for the resin and depth, extra draft for a texture, and how much a width or diameter shrinks over the depth. Based on: DuPont, General Design Principles – Module I, p. 12, Table 3.01.
Part
Depth of draw h = depth of the wall in the direction the mould opens. Up to 25 mm counts as a shallow draw in the table of the source.
Surface and draft
- noteDraft from Table 3.01 Acetal (POM, e.g. Delrin), shallow draw: 0 to 0.25° for a smooth, lustrous surface DuPont p. 12
- metPlanned draft 0.5° against 0 to 0.25° DuPont p. 12
- notePolish where the smallest draft is wanted, a good polish in the direction of draw helps ejection DuPont p. 12
- noteEjector pins place the pins so that the part does not distort, with enough pin area so that it is not punctured or marked; stripper plates or rings where needed DuPont p. 12
- noteCorners smooth radii ease ejection; fillet radius about half the wall thickness, at least 0.5 mm DuPont p. 12
- Own reading of the table: exactly 25 mm counts as a deep draw (safe side); a texture between multiples of 0.025 mm is taken in proportion.
- The table of the source is for DuPont resins; for other grades ask the supplier and check the first parts from the mould.
Calculation with your numbers Pro
Calculation in SI units (mm, N, MPa), as in the sources.
Draft angle
Draft from Table 3.01 (smooth surface)
Formula shallow draw (h < 25 mm)
With your numbers h = 20 mm → 0 to 0.25°
Recommended draft = 0.25 °
Formula table value
With your numbers 0 to 0.25°
Offset of each wall over the depth (planned draft) = 0.1745 mm
Formula e = h · tan θ
With your numbers 20 · tan 0.5° = 0.1745
Change of a width or diameter over the depth = 0.3491 mm
Formula Δ = 2 · h · tan θ
With your numbers 2 · 0.1745 = 0.3491
Width or diameter at the deep end = 39.65 mm
Formula W_h = W − 2 · h · tan θ
With your numbers 40 − 0.3491 = 39.65
Saved designs in this browser
No saved designs for this tool yet.
Saved in this browser and, when you are logged in, in your account. Status as the tool calculates it now.
Schematic section, draft exaggerated, not to scale. Both walls drafted: the width or diameter is smaller by 2 · h · tan θ at the deep end.