SnapFitCalc
Open calculator

Tools

Small calculators and guides around snap-fits and plastic part design. Every value with its formula and source.

Buckling of struts and tubes

Compressed strut, standoff or rib with hinged, fixed or free ends, or a tube under external pressure: critical load or pressure, compressive stress and the safety against buckling. Based on: DuPont, General Design Principles – Module I, p. 21–22, 42.

In this browser, and in your account when you are logged in.

Case

Start values are an example. Use the tangent modulus at the compressive stress, for a lasting load the creep modulus (source p. 22, 25).

Strut

Rectangular section

Round section

Tube under external pressure

Critical buckling load
248.7 N
Safety against buckling
4.974
Compressive stress
1.667 MPa
Moment of inertia
22.5 mm⁴
  • metBuckling S = 4.974; the source recommends a safety factor of 3 to 4 DuPont p. 22
  • noteModulus use the tangent modulus at the compressive stress; for a lasting load the creep modulus at the design time and temperature DuPont p. 22, 25
  • noteCompression σ_c = F / A = 1.667 MPa: short struts fail by crushing; buckling governs when the buckling load is below the allowable load under pure compression DuPont p. 21–22
  • noteEnds the ends of most plastic parts are not ideally hinged; other end conditions change the critical load (cases of table 4.05) DuPont p. 22, table 4.05
  • Ribs higher than 5 times their thickness that are loaded in compression should be checked for buckling (source p. 30).
  • The formulas apply to short loads (10 to 20 minutes) in the elastic range (source p. 21).

Calculation with your numbers Pro

Calculation in SI units (mm, N, MPa), as in the sources.

Strut

Moment of inertia about the weaker axis = 22.5 mm⁴

Formula I = b · h³ / 12 (h = smaller side)

With your numbers 10 · 3³ / 12 = 22.5

Source: DuPont, Engineering Polymers – General Design Principles, Module I, table 4.01 (p. 33)
Cross-section = 30 mm²

Formula A = b · h

With your numbers A = 30

Source: geometry
Compressive stress = 1.667 MPa

Formula σ_c = F / A

With your numbers 50 / 30 = 1.667

Source: DuPont, Engineering Polymers – General Design Principles, Module I, p. 21
Critical buckling load (both ends hinged) = 248.7 N

Formula F_C = π² · E · I / l²

With your numbers π² · 2800 · 22.5 / (1 · 50)² = 248.7

Source: DuPont, Engineering Polymers – General Design Principles, Module I, p. 22, table 4.05 (p. 42)
Safety against buckling = 4.974

Formula S = F_C / F (3 … 4 recommended)

With your numbers 248.7 / 50 = 4.974

Source: DuPont, Engineering Polymers – General Design Principles, Module I, p. 22
Saved designs in this browser

No saved designs for this tool yet.

Saved in this browser and, when you are logged in, in your account. Status as the tool calculates it now.

F = 50 Nl = 50Cross-sectionb = 10h = 3

Schematic, not to scale; dashed: buckled shape. Hinged ends can turn, fixed ends cannot; a free end can move sideways.