SnapFitCalc
Open calculator

All articles

Design rules

Lead angle, return angle and friction

How the two hook angles set the mating and the release force, and when a joint can no longer be released.

R ≥ 1.50α = 30°α′ = 45°L = 15.00 mmt = 3.00Y = 2.00 mmSection at the rootb = 6.00t = 3.00

A hook usually has a gentle ramp on the entrance side and a steeper face on the retraction side. The small lead angle α keeps the mating force low; the steep return angle α′ makes the joint hard or impossible to release (BASF, Part III, Fig. III-1).

Both forces follow from the deflection force P and the friction coefficient μ: W = P · (μ + tan α) / (1 − μ · tan α). The release force uses α′ in the same formula. When μ · tan α′ reaches 1, the joint is self-locking and cannot be pulled apart (BASF, Fig. III-2; Bayer, p. 14).

Friction depends on the material pair, the surface and the speed. Two parts of the same plastic usually have higher friction than plastic on steel (Bayer, Table 3; BASF, Table IV-II).

Key points

  • Gentle lead angle for easy joining, steep return angle for holding.
  • Separable joints need μ · tan α′ < 1.

Open the calculator

Sources

  • BASF Snap-Fit Design Manual, Part III, Fig. III-1, III-2; Table IV-II
  • Bayer, Snap-Fit Joints for Plastics, p. 14, Table 3

Articles summarise the sources in our own words. They do not replace the design guides, your datasheet or tests with real parts.