SnapFitCalc
Open calculator

Cooling simulation

How long each spot of a cross-section stays hot, and where sink marks can start. Calculated here in your browser. Nothing to install, and your geometry stays on your computer.

Stress and strain Cooling Mould filling 3D part check

1. Part

    2. Material

    Values from the material library are guide values. Use the data of your grade for a release.

    3. Supports and loads

    Click an edge in the picture, or choose it here.

    4. Mesh

    The mesh refines itself where the stress changes quickly. You rarely need to change this.

    Result picture

    The circle marks the peak. Dashed line: the part without load. Drag to move, Ctrl + wheel to zoom.

    Series: change one dimension

    Calculates the part several times and shows where the strain fits, for example for the root radius or the length of the arm.

    Natural frequencies

    The first ways the part vibrates, with the same supports (the loads do not count). Useful when a clip or a tongue sits near a motor or rattles.

    How this is calculated, and its limits

    • Finite elements with quadratic triangles (Cook, Malkus, Plesha, Witt: Concepts and Applications of Finite Element Analysis, 4th ed. 2002). Mesh generation after Ruppert (J. Algorithms 18, 1995), mesh refinement after Zienkiewicz and Zhu (Int. J. Numer. Meth. Eng. 24, 1987).
    • Automatic tests compare every version with known exact solutions: uniform tension, bent beam (Timoshenko and Goodier), hole in a large plate (Kirsch 1898), thick ring under pressure (Lamé).
    • Limits: flat (2D) model of one cross-section, linear material, small deflections, no contact, no creep, no fatigue. Plastics get softer at higher strain, so stress at high strain is overestimated.
    • Cooling: heat conduction in the cross-section with constant diffusivity, and the mould wall at mould temperature from the first moment. Checked against the exact solution for a plate (Carslaw and Jaeger). Real parts also lose contact with the mould as they shrink, so real times can be longer.
    • Mould filling: Hele-Shaw flow with control volumes (Hieber and Shen, J. Non-Newtonian Fluid Mech. 7, 1980), constant viscosity, no cooling during the fill. Checked against the exact radial and straight flow and two parallel channels of different thickness.
    • A fast first check. Verify with test parts before release.