Material
Secant modulus and moisture
Why the modulus from the datasheet is often too high for a snap-fit, and why nylon has to be checked twice.
During joining the material is briefly loaded beyond its linear range. The ordinary modulus of elasticity is then replaced by the strain-dependent secant modulus: the stress at the design strain divided by that strain (Bayer, p. 7 and p. 12, Fig. 14). Use the strain on which the undercut was dimensioned.
Nylon takes up moisture. Dry as moulded, the datasheet values apply; at 50 % relative humidity stiffness and holding force drop while the possible deflection increases. Both states should be checked (BASF, Part III).
Key points
- Forces with the secant modulus at the design strain.
- Nylon: check dry and conditioned.
Sources
- Bayer, Snap-Fit Joints for Plastics, p. 7 and p. 12 (Fig. 14)
- BASF Snap-Fit Design Manual, Part III, p. III-2