The worked examples of BASF and Bayer, each ready to open in the calculator with the values of the source.

Each example below names its source and what the source gives as the result. Open it in the calculator and compare the numbers step by step.

BASF design example 1 (PBT GF, find max deflection)

From the source

BASF Snap-Fit Design Manual, Design Example #1: Ultradur B4300 G3, L = 15, t = 3, b = 6 mm, E = 4830 MPa, ε₀ = 2.5 %, μ = 0.3, α = 30°. BASF: Y max = 2.59 mm, P = 72.45 N, W = 76.9 N (Q = 2.07, matches curve 5).

Open in the calculator

BASF design example 2 (POM, check)

From the source

BASF Design Example #2: acetal, t = 0.063 in (1.6 mm), Y = 0.090 in (2.286 mm), L = 0.225 in (5.715 mm); BASF reads Q = 2.7 and gets 6.2 % (the digitized curve 5 gives Q ≈ 2.6 and about 6.5 %). E, μ and b are not part of the example: values of the library (POM) and b = 6 mm.

Open in the calculator

Bayer example 1 (tapered beam, PC)

From the source

Bayer, Snap-Fit Joints for Plastics, calculation example 1: thickness taper to h/2, l = 19 mm, h = 3.28 mm, b = 9.5 mm, Es = 1815 MPa, y = 2.4 mm, μ = 0.6, α = 30°. Bayer: ε = 2 %, P = 32.5 N, W = 58.5 N. ε₀ = 4 % (Bayer Table 2, PC); no Q curve for this case (classical, as Bayer).

Open in the calculator

Bayer example: ring segment (PC/ABS, find max deflection)

From the source

Bayer, Fig. 20 (p. 17): design type 2, ring segment r₂ = 20 mm, h = 2.5 mm, θ = 75°, l = 25.4 mm, εpm = 0.6 · 2.5 % = 1.5 % (frequent separation). Bayer: y = 2.11 mm. E, μ and angles are not part of the example: values of the library (PC/ABS) and start values.

Open in the calculator

BASF example: L-shaped snap (PA GF, slot length)

From the source

BASF Snap-Fit Design Manual, Part V, L shaped snap example (Ultramid 8233), converted from inches: ε₀ = 2.5 %, t = 0.1 in (2.54 mm), L₁ = 0.5 in (12.7 mm), R = 0.12 in (3.048 mm), b = 1 in (25.4 mm), E = 1.31·10⁶ psi (9032 MPa), Y = 0.38 in (9.652 mm). BASF: min. slot length L₂ = 0.954 in (24.2 mm), P = 88 lb (391 N). μ and angles are not part of the example (start values).

Open in the calculator

BASF example: U-shaped snap (deflection at 1 lb)

From the source

BASF Part V, U shaped snap example #1, converted from inches: E = 534 000 psi (3682 MPa), t = 0.1 in (2.54 mm), b = 1 in (25.4 mm), R = 0.15 in (3.81 mm), L₁ = 1.4 in (35.56 mm), L₂ = 0.973 in (24.71 mm). BASF: Y = 0.064 in (1.63 mm) at P = 1 lb (4.45 N); here Y = 1.6256 mm gives P ≈ 4.45 N. ε₀, μ and angles are not part of the example (start values).

Open in the calculator

BASF example: U-shaped snap, case 2 (shorter free leg)

From the source

BASF Part V, U shaped snap, case 2 (L₂ = L₁ + L₃), converted from inches: as example #1 but L₁ = 0.7 in (17.78 mm), L₃ = 0.273 in, so L₂ = 0.973 in (24.71 mm). BASF: Y = 0.012 in (0.305 mm) at P = 1 lb (4.45 N); here Y = 0.3048 mm gives P ≈ 4.45 N. ε₀, μ and angles are not part of the example (start values).

Open in the calculator

Bayer example II as slotted ring (ring segments)

From the source

Bayer, calculation example II (Fig. 20): segment of a ring r₂ = 20 mm (d = 40 mm), h = 2.5 mm (dᵢ = 35 mm), θ = 75°, l = 25.4 mm, thickness tapered to h/2, εpm = 0.6 · 2.5 % (frequent separation). Bayer: y = 2.11 mm per segment, so y pm = 4.22 mm. Number of segments n = 4, Es, μ and angles are not part of the example (library PC/ABS, start values).

Open in the calculator

Bayer example: annular snap, lamp housing

From the source

Bayer, calculation example annular snap joint (lamp housing, Makrolon): d = 200 mm, t = 2.5 mm, y = 2 × 1 mm, α = 30°, μ = 0.6, Es = 2200 MPa. Bayer: ε = 0.5 %, P = 748 N, W = 1346 N.

Open in the calculator

Sources

  • BASF Snap-Fit Design Manual, Parts IV and V
  • Bayer, Snap-Fit Joints for Plastics, sections B and D

Articles summarise the sources in our own words. They do not replace the design guides, your datasheet or tests with real parts.